Augusta, Richmond County

DOUBLE TREE HOTEL OF AUGUSTA OUTDOOR POOL 2

2651 PERIMETER PKWY AUGUSTA, GA 30909

Pool
Latest score
100
May 27, 2026
City
Augusta
County
Richmond
Inspections
15

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 27, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Nov 17, 2025

Routine

Score: 851 violation

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

ph was 6.8

Nov 14, 2025

Routine

Score: 851 violation

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

ph was 7.0

May 22, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 19, 2025

Permit/Opening

Score: 793 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

ph=6.8

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

Should be appx. 75 GPM.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Adjust TA, calcium hardness (TA min 60 ppm, hardness min 150ppm).

Apr 24, 2025

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

Phone must work if inside phone handset off hook.

Apr 17, 2025

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

During inspection, inspector determined this outdoor phone off hook, indoor phone will not dial 911. (get open line, static). Correct so that each phone operates independently (if one off hook, other will dial 911). Close and lock all access to pool until permitted.

Apr 15, 2025

Permit/Opening

Score: 812 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(b) - (b) openings in the barrier shall not allow passage of a four inch diameter sphere.

15 ptsCorrected: NoRepeat: No

Repair fence where not attached to fence posts.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(4) - (4) depth markers for spas. public spas shall have permanent depth markers with numbers and letters a minimum of four inches high plainly and conspicuously visible from all obvious points of entry and in conformance with subsections (a) thru (f) belo

4 ptsCorrected: NoRepeat: No

Repair loose tiles (depth marking tiles).

Mar 13, 2025

Permit/Opening

Score: 783 violations

3 - compliant drain covers secure, present and no cracks

Regulation: 511-3-5-.23(5)(f) - (f) broken, unsecured, or missing main drain, or any submerged suction outlet cover/grate

15 ptsCorrected: NoRepeat: No

One of 2 drain covers has hole in top. Replace drain covers with new covers 9keep records of install date/expiration date of covers. Provide copy to RCHD).

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

Unstick flowmeter float (changed during inspection).

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Replace missing pool rules signs.

Jan 27, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Dec 16, 2024

Routine

Score: 812 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

pH < 7

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed skimmers with heavy leaf accumulation. C/A: Clear.

Sep 4, 2024

Routine

Score: 802 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: YesRepeat: No

pH < 7.2. Added soda ash to correct pH.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Keep records 2X/day of pH, chlorine.

Jun 11, 2024

Routine

Score: 853 violations

3 - compliant drain covers secure, present and no cracks

Regulation: 511-3-5-.23(5)(f) - (f) broken, unsecured, or missing main drain, or any submerged suction outlet cover/grate

15 ptsCorrected: NoRepeat: No

Unable to see drain covers due to cloudiness.

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Mains not clearly visible due to cloudiness.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Untangle throw ring rope; must be 1 1/2 times width of pool.

Feb 16, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jan 19, 2024

Permit/Opening

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Need "No Diving" at shallow end of pool (one each side and end) (3 1/2 ' end). Should be 4 inch letters, one inch stroke.