Kingsland, Camden County

Hawthorn Suites Kingsland

1323 E KING AVE KINGSLAND, GA 31548

Pool
Latest score
78
May 22, 2026
City
Kingsland
County
Camden
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 22, 2026

Re-inspection

Score: 784 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: YesRepeat: Yes

At the beginning of the inspection, the emergency phone had no dial tone (there appeared to be no power to the phone). COS: An employee worked on the phone / phone connection and was able to restore functionality to the phone. The phone was tested and proved capable of connecting to 9-1-1.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

At time of inspection, the pressure gauge is cracked and faded. Replace the pressure gauge.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

At time of inspection, the "Warning: No Lifeguard on Duty..." sign is missing. PIC states the signs will be installed ASAP.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

At time of inspection, observed numerous chipped/worn areas in the marcite on the walls and floor of pool. The pool will need resurfacing before next season.

May 5, 2026

Permit/Opening

Score: 796 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.23(5)(g) - (g) failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required.

15 ptsCorrected: NoRepeat: No

At time of inspection, observed that there is no fence/gate blocking people from walking around the far side of the building to access the pool and spa. The original fencing was removed when the space was opened/connected to the Wingate by Wyndham (same owner). The pool and spa must be completely enclosed by a barrier.

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

At time of inspection, the gate from the pool to the parking lot is not self-closing or self-latching. Ensure that all gates automatically swing closed and latch each time (without having to lift up on or manipulate the gate to get it to close). PIC locked this gate, until it can be fixed.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

At time of inspection, the emergency phone is not operational. Fix/replace the emergency phone and ensure that it is fully functional.

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

At time of inspection, the free chlorine level registered at 1.14 ppm (free chlorine must be 2.00 - 10.00 ppm). Increase chlorine output to within range.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

At time of inspection, the pressure gauge is cracked and faded. Replace the pressure gauge.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

At time of inspection, the following signs are missing from the pool area: "Pool Risks" (min. 1" lettering; Violation of code: [511-3-5-.18(12)(c)]), "Warning: No Lifeguard on Duty..." (min. 4" lettering; Violation of Code: [511-3-5-.18(12)(b)]), Occupancy / bather load (Violation of Code: [511-3-5-.18(13)(c)]). Acquire the signs and post.

Dec 17, 2025

Re-inspection

Score: 895 violations

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: Yes

At time of inspection, the cyanuric acid (CYA) level registered at 179 ppm (CYA must be 90 ppm or less). CPO will gradually drain and add water, to ensure that CYA is below 90 ppm.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: Yes

At time of inspection, the pressure gauge on the filter is faded and cracked. Replace the pressure gauge.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: Yes

At time of inspection, the "WARNING: NO LIFEGUARD ON DUTY..." sign is missing. PIC states that signs have been ordered and will be installed ASAP.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: Yes

At time of inspection, the "Pool Risks" sign is missing. PIC states the sign has been ordered and will be installed ASAP.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

At time of inspection, there are numerous chipped areas in the marcite on the floor of the pool. The pool needs resurfacing in near future.

Dec 9, 2025

Re-inspection

Score: 747 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

At time of inspection, the gate at the parking lot entrance to the pool area is not self-latching. The latch on the gate does not line up with the latch on the fence, preventing the gate from self-latching (the gate will not latch, unless the gate is lifted slightly). Repair/re-align gate latch, so that the gate is self-closing. PIC locked the gate to the parking lot, until it can be fixed.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: Yes

At time of inspection, the free chlorine (FCL) level registered at 12.69 (FCL must be within the range of 2.00 - 10.00 ppm). The level has been lowered significantly since the last inspection, but the level must be below 10.00 ppm. CPO will drain some more water and adjust the chlorinator, to ensure that the free chlorine level is within the acceptable range. The pool must remain closed, until all critical violations have been corrected AND the pool has passed re-inspection.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

At time of inspection, the cyanuric acid (CYA) level registered at 122 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, in an attempt to lower the CYA level, as well as the free chlorine level. The CYA level has decreased since the last inspection, but is still above 90 ppm.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: Yes

At time of inspection, the pressure gauge on the filter is faded and cracked. Replace the pressure gauge.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: Yes

At time of inspection, the "WARNING: NO LIFEGUARD ON DUTY..." sign is missing. Replace the "WARNING: NO LIFEGUARD ON DUTY..." sign (lettering must be at least 4" high). PIC states she has ordered the signage & will have it posted as soon as it arrives.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: Yes

At time of inspection, the "Pool Risks" sign is missing. Replace "Pool Risks" sign (lettering must be at least 1" high). PIC states she has ordered the signage and will have it posted as soon as it arrives.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

At time of inspection, there are numerous chipped areas in the marcite on the floor of the pool. The pool needs resurfacing in near future.

Dec 2, 2025

Re-inspection

Score: 746 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

At time of inspection, the free chlorine level registered at 22.19 ppm (free chlorine level must not exceed 10 ppm). It is believed that the pool was shocked recently. PIC states she will drain some water and add some fresh water, in order to lower the free chlorine level to within the acceptable range (2.00-10.00 ppm). The pool must remain closed, until the free chlorine level is within the acceptable range AND the pool has passed re-inspection.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 179 ppm (CYA must be 90 ppm or less). PIC states she will drain some water and add some fresh water, in an attempt to lower the CYA level, as well as the free chlorine level.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

At time of inspection, the pressure gauge on the filter is faded and cracked. Replace the pressure gauge.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: Yes

At time of inspection, the "WARNING: NO LIFEGUARD ON DUTY..." sign is missing. Replace the "WARNING: NO LIFEGUARD ON DUTY..." sign (lettering must be at least 4" high). PIC states she is ordering the signage & will have it posted as soon as it arrives.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

At time of inspection, the "Pool Risks" sign is missing. Replace "Pool Risks" sign (lettering must be at least 1" high). PIC states she is ordering the signage and will have it posted as soon as it arrives.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

At time of inspection, there are numerous chipped areas in the marcite on the floor of the pool. The pool needs resurfacing in near future.

Oct 30, 2025

Permit/Opening

Score: 749 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

At time of inspection, the gate at the parking lot entrance to the pool area is not self-latching (during course of inspection, observed wind blowing gate back and forth). All gates must be self-closing and -latching. Repair/re-align gate, so that it is self-latching.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

At time of inspection, the emergency phone is not operational (no sound or dial tone can be heard, as if there may be no power available to the phone). Repair/replace emergency phone, so that it is capable of connecting to emergency services (capable of dialing "9-1-1.")

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

At time of inspection, the rope is missing from the ring buoy. A minimum 1/4" diameter throwing rope 1.5 times the maximum width of the pool must be firmly attached to the ring buoy.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 173 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, until CYA is below 90 ppm.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

At time of inspection, the pressure gauge on the filter is faded and cracked. Replace the pressure gauge.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

At time of inspection, the "Pool Risks" sign is missing. Replace "Pool Risks" sign (lettering must be at least 1" high).

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

At time of inspection, the "WARNING: NO LIFEGUARD ON DUTY..." sign is missing. Replace the "WARNING: NO LIFEGUARD ON DUTY..." sign (lettering must be at least 4" high).

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

At time of inspection, the peak occupancy and hours of operation sign is missing. Replace peak occupancy and hours of operation signage (lettering should be at least one inch high).

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

At time of inspection, there are numerous chipped areas in the marcite on the floor of the pool. The pool needs resurfacing in near future.

Nov 22, 2024

Re-inspection

Score: 944 violations

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: Yes

At time of inspection, the pressure gauge is still broken. PIC has asked the CPO to replace the pressure gauge.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: Yes

At time of inspection, the "No lifeguard on duty" sign is still missing. PIC has contacted Jeff's Pool store and is in the process of acquiring the sign.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: Yes

At time of inspection, the "Pool Risks" sign is still missing. PIC has contacted Jeff's Pool store and is in the process of acquiring the sign.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: Yes

At time of inspection, the peak occupancy sign is still missing. PIC has contacted Jeff's Pool store and is in the process of acquiring the sign.

Nov 21, 2024

Routine

Score: 795 violations

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: No

At time of inspection, the pole and hook are missing. The PIC is in the process of acquiring a pole and hook. PIC closed the pool/spa area and placed a sign on the door (the gate is secure). The pool/spa area must remain closed, until a pole and hook are present, AND the pool has passed re-inspection.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

At time of inspection, the pressure gauge is broken. The pressure gauge must be replaced.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

At time of inspection, the "No lifeguard on duty" sign is missing. PIC is in the process of acquiring the sign.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

At time of inspection, the "Pool Risks" sign is missing. PIC is in the process of acquiring the sign.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

At time of inspection, the peak occupancy sign is missing. PIC is in the process of acquiring the sign.

Jun 20, 2024

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, cyanuric acid (CYA) level registered as "Hi" on the test kit. CYA must be 90 ppm or less, or chlorine efficacy will be diminished. CPO will drain some water and add some fresh water.

Nov 20, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Nov 15, 2023

Permit/Opening

Score: 813 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

At time of inspection, the emergency phone was non-operational (no dial tone / power). PIC contacted Hargray (phone service provider) and a technician will troubleshoot the phone ASAP.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

At time of inspection, observed a loose handrail at the steps leading into the pool. PIC contacted CPO and asked him to tighten the handrail ASAP.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

At time of inspection, observed the lack of "Pool Risks" sign in the pool area. PIC stated the CPO had ordered the signs several days ago and will install them as soon as they arrive.