Kingsland, Camden County

Settlers Hammock

101 SETTLERS HAMMOCK WAY KINGSLAND, GA 31548

Pool
Latest score
87
Jun 4, 2026
City
Kingsland
County
Camden
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 4, 2026

Permit/Opening

Score: 873 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, there is no flow meter installed. Install a flow meter.

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: NoRepeat: No

At time of inspection, the float line is missing. Replace the rope and float line.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) registered as "Hi" on the test kit. CPO will drain some water and add fresh water, to ensure that CYA is below 90 ppm.

Apr 24, 2025

Permit/Opening

Score: 745 violations

8 - chemical feeder operational and approved

Regulation: 511-3-5-.16(1) - (1) disinfectant equipment and chemical feeders, such as flow-through chemical feeders, electrolytic chemical generators, mechanical chemical feeders, chemical feed pumps, and automated controllers shall comply with the requirements of nsf standard 5

15 ptsCorrected: YesRepeat: No

Chlorine tablets in skimmers due to chlorinator breaking/Removed tablets and told to install chlorinator as soon as it arrives. Shocking pool currently to maintain disinfectant levels at 2.00-10

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: NoRepeat: No

At time of inspection, there is no float line present. CPO will procure and install a float line.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time if inspection, the cyanuric acid level was above 90 ppm (test kit read "Hi"). CPO will drain some water and add some fresh water.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

No maximum bather load listed/Install sign reflecting max 57

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

No directional arrows on piping/Mark

Sep 18, 2024

Routine

Score: 793 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

At time of inspection, the emergency phone was not functioning. CPO tried a replacement phone, but the phone line is bad (no dial tone or sound at all). CPO will contact management to troubleshoot.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time if inspection, the cyanuric acid level was above 90 ppm (test kit read "Hi"). CPO will drain some water and add some fresh water.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

At time of inspection, the ladder was loose. CPO will secure the ladder.

Apr 25, 2024

Permit/Opening

Score: 904 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

At time of inspection, the combined chlorine registered at 1.05 ppm (combined chlorine must be 0.4 ppm or less). CPO will drain some water and add fresh water.

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: NoRepeat: No

At time of inspection, there is no float line present. CPO will procure and install a float line.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(e ) - (e) soap dispensers for providing either liquid or powdered soap shall be provided at each lavatory. the dispenser shall be of all metal or plastic. no glass shall be permitted in these units.

1 ptsCorrected: NoRepeat: No

At time of inspection, the men's restroom lacked soap (the empty soap dispenser was removed from wall and was sitting on the back of the toilet). CPO states that management company is in the process of updating the restrooms and will ensure that both restrooms are stocked with soap, paper towel, and toilet paper.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

At time of inspection, both restrooms lack paper towel (both dispensers were empty). CPO states that management company is in the process of updating the restrooms and will ensure that both restrooms are stocked with soap, paper towel, and toilet paper.