College Park, Clayton County

LaQuinta Inn & Suites

4820 MASSACHUSETTS BLVD COLLEGE PARK, GA 30337

Pool
Latest score
100
May 15, 2026
City
College Park
County
Clayton
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 15, 2026

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 13, 2026

Permit/Opening

Score: 852 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: YesRepeat: No

Observed 1 entry way door from main building not self latching. COS: PIC adjusted so entry way door self closed/self latched. Advised to monitor both pool entry way doors and ensure they continue to self close and self latch. The two iron gates leading to parking lot are always locked to bathers as per PIC.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not working. Advised to repair and ensure direct 911 access and that 911 operator can clearly hear caller and has location of pool. Advised to post pool address next to emergency phone.

Aug 4, 2025

Routine

Score: 991 violation

31 - dressing showers: clean, maintained, hot and cold water available

Regulation: 511-3-5-.19(1)(e ) - (e) hot and cold water under pressure shall be provided in dressing facility showers.

1 ptsCorrected: NoRepeat: No

Deck shoer inoperable. Advised PIC deck showers shall have hot & cold water available at all times.

May 20, 2025

Permit/Opening

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: YesRepeat: No

Observed the maximum occupancy sign not posted. Advised to obtain the correct sign. CPO emailed a written statement stating sign would be ordered. today. COS

May 28, 2024

Permit/Opening

Score: 972 violations

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Deck has cracks in several areas, deck shall be maintained, Coping around pool has gaps. The deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed pool interior surface has damage. COA Resurface during pool's off season. Must resurface prior to next pool season

Jun 5, 2023

Permit/Opening

Score: 991 violation

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

511-3-5.06(1) Constructive joint were coping meets the desk is in need of repair in multiple areas. Must be water tight and shall not allow passage of water

Jun 2, 2023

Permit/Opening

Score: 853 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Phone not working. Phone must work

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine too high. Must be within 2-10

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Ph too high. Must be between 7.2-7.8