Lake City, Clayton County

American Deli

5656 JONESBORO RD STE 108 LAKE CITY, GA 30260

Food
Latest score
96
Mar 17, 2026
City
Lake City
County
Clayton
Inspections
3

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 17, 2026

Routine

Score: 962 violations

11C - approved thawing methods used

Regulation: 511-6-1.04(6)(c) - thawing (c)

3 ptsCorrected: YesRepeat: No

Observed frozen tilapia thawing in meat sink in main kitchen without running water. COS: PIC turned on running water less than 70 degrees F. CA: Use proper thawing methods to thaw TCS food items.

17D - adequate ventilation and lighting; designated areas used

Regulation: 511-6-1.07(4)(b) - designated areas for employee activity, located to prevent contamination of food, equipment, utensils, linens, & single service articles (c)

1 ptsCorrected: YesRepeat: No

Observed employee personal items (ice cream & popsicles) in main kitchen reach in freezer. COS: PIC moved to designated area. CA: Keep employee personal items in designated area to prevent cross contamination.

Oct 1, 2025

Routine

Score: 981 violation

16A - hot and cold water available; adequate pressure

Regulation: 511-6-1.06(1)(g),(h) - water supply, capacity; pressure (pf)

2 ptsCorrected: NoRepeat: No

Observed hot water unavailable at hand sink. Advised PIC hot water shall be at least 85F.

Jun 27, 2025

Issued Provisional Permit

Score: 952 violations

11A - proper cooling methods used: adequate equipment for temperature control

Regulation: 511-6-1.04(6)(e) - cooling methods (pf, c)

3 ptsCorrected: YesRepeat: No

Observed rice in the prep top and the walk in cooler cooling with the lids on tight. Advised on proper cooling methods. COS: PIC removed the lids.

16A - hot and cold water available; adequate pressure

Regulation: 511-6-1.06(1)(g),(h) - water supply, capacity; pressure (pf)

2 ptsCorrected: YesRepeat: No

Observed no hot water at two hand sinks. Advised PIC hot water shall be available at all times. COS PIC restored hot water to required minimum temperature.