STOCKBRIDGE, Clayton County

Sleep Inn & Suites

7423 DAVIDSON CIR W STOCKBRIDGE, GA 30281

Pool
Latest score
73
Apr 14, 2026
City
STOCKBRIDGE
County
Clayton
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 14, 2026

Permit/Opening

Score: 735 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed the chlorine reading at 1ppm. Advised CPO Chlorine shall read between 2-10ppm. Advised to adjust.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed the pool not meeting the required turnover rate of 6 hours. Advised CPO pool shall meet a minimum of 6 hours.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed no weirs in the skimmer baskets. Advised to provide.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(g) - (g) a minimum four foot deck width shall be provided on the sides and rear of any diving equipment or waterslide stairs. a deck clearance of forty-eight inches shall be provided around all deck equipment.

2 ptsCorrected: NoRepeat: No

Observed etching on the bottom of the pool and cracks on the deck. Advised to repair.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Observed the piping unidentified. Advised CPO all piping shall be marked to identify each pipe. Advised to correct.

Jul 2, 2025

Re-inspection

Score: 952 violations

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: YesRepeat: Yes

No diving lettering on deck shall be 4 inches and permanent. PIC has agreed to have corrected prior 2026 pool season.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Observed deep etching in multiple are of pool. Pool shall be resurfaced prior to the 2026 pool season in order to obtain 2026 permit

Jun 23, 2025

Re-inspection

Score: 851 violation

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Observed pool cloudy(very). Pool water shall be clear. Advised to restore clarity. Reinspection and reinspection fee required prior to reinspection.

May 28, 2025

Permit/Opening

Score: 824 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed PH @ 7.0 .PH shall be no less then or higher than the required level. Advised to raise ph level. Pool is to remain closed until corrected and rechecked by EH.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed damaged universal no diving symbol tiles and depth marker tiles also damaged / pulling away from deck. Advised PIC tiles shall be permanently placed only on the deck.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: Yes

Observed no theoretical peak occupancy near the entrance of the pool enclosure. Advised PIC A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy. COS: Had PIC relocate theoretical peak occupancy to entry gate of pool enclosure.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed deep etching in multiple are of pool. Pool shall be resurfaced prior to the 2026 pool season in order to obtain 2026 permit

May 3, 2024

Permit/Opening

Score: 982 violations

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed no universal no diving symbol at two of the depth markers. Advised PIC The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: YesRepeat: No

Observed no theoretical peak occupancy near the entrance of the pool enclosure. Advised PIC A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy. COS: Had PIC relocate theoretical peak occupancy to entry gate of pool enclosure.