Mar 27, 2026
Re-inspection
1025 EAST WEST CONNECTOR STE 200 AUSTELL, GA 30106-8513
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Routine
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed emergency phone out of order. Heard only static, no dial tone.
Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.
Observed inspection report from 2023 posted. CA: Most recent inspection must be posted in public view.
Routine
Routine
Observed chlorine reading at 14ppm, above max
Observed pH reading at 8.0, above max
Re-inspection
Re-inspection
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
Observed no physical copy of chemical log. CA: Chemical log shall be onsite and available to health authority.
Routine
Regulation: .17((1)(c) - proper disinfectant level
Observed chlorine level at 0ppm.
CA: Chlorine level shall be maintained at 2ppm-10ppm.
Observed pH level at 7.0.
CA: pH level shall be maintained at a 7.2-7.8.
Observed pool chemicals spilled out on the floor near pumps. Observed several bottles of chemicals on the ground.
CA: Pool chemicals shall be stored in a way that prevents hazards.
Re-inspection
Install compliant cover (self-closing, self-latching) on second vacuum line. Currently using non-compliant cover. Install handle on vacuum line valve.
Permit/Opening
Phone not working - no dial tone, very staticy
Tighten connection where filter connects to pipe (multi-port) - leak
Attach rope to life ring. Hang shepherd's hook on wall.
Install compliant cover on second vacuum line. Install handle on vacuum line valve.
Sweep deck. Patch large opening in deck drain.
Mount signage: "WARNING NO LIFEGUARD ON DUTY", 911 sign, "RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY (min. 4" letters), pool occupancy (min. 4" letters), and "Pool Risks" sign (min. 1" letters)
Replace missing boot caps on ladder