MIRADOR AT IDLEWOOD (Upper Pool)

1250 BROCKETT RD CLARKSTON, GA 30021

Pool
Latest score
80
Jun 4, 2026
City
Clarkston
County
DeKalb
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 4, 2026

Permit/Opening

Score: 804 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g) an operable telephone shall be readily available at all times. Observed: the phone is operable, but unable to connect to 911 due to maximum amount of calls being reached

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) free chlorine shall not excess 10 ppm. The current level is 21.32 ppm

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: Yes

13-189(c)(2) cyanuric acid levels shall not exceed 100 ppm. Observed: cyanuric acid level at 198 ppm

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(k) each pool shall be supplied with a readily available first aid kit, there is no first aid kit available

May 20, 2026

Permit/Opening

Score: 698 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(2) entry to pool shall be through a self-closing, self-latching gate. Observed: gate does not self-close, no spring present on gate. Advised to keep gate closed, as it was wide open upon arrival

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

13-189(c)(6) water shall be of such clarity that main drains are visible, main drains are currently not visible

10 - pump: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

13-190(a) all circulation systems, including pumps shall function properly. observed: pump not functioning, no water running through

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(a) equipment must be ran to ensure one turnover every 6 hours. Observed: no flow reading, pump is not operating. Flow meter must read 89 GPM

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-190(a) all circulation systems, including skimmers, shall function properly. Observed: water level too low to observe skimmer function

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: Yes

13-189(c)(2) cyanuric acid levels shall not exceed 100 ppm. Observed: cyanuric acid level at 128 ppm

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m) safety rules shall be easily readable from pool area. Observed: no hours of operation or number for bather load sign. Sign is required to read 52 occupants

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(i) each pool facility shall have a departmentally approved EAP. Observed: no EAP present, provided management with template. They are in the process of making the EAP

Jul 16, 2025

Permit/Opening

Score: 961 violation

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-190(a) skimmers must be clean and well maintained. Half of this pool's skimmers were ill maintained.

Jun 25, 2025

Permit/Opening

Score: 763 violations

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

13-197(a) and 13-197(i) The pool's chemical feeder was not working, and the CPO admitted to having his staff shock the pool before the inspection to get the FCL level to proper range

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-205(b)(1) the turnover rate for the pool was low

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2) the cyanuric acid levels of the pool exceeded 100

Jul 5, 2024

Permit/Opening

Score: 942 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): an adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate. -flow meter was not functioning at time of inspection. -CPO verbalized that the plan was to replace flow meter.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): visible scum on pool surfaces shall be removed immediately. -observed considerable staining at the bottom of the pool.

Aug 2, 2023

Re-inspection

Score: 793 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): the free chlorine must be between 3.0-10.0ppm in all parts of the pool. Conducted many tests in which the chlorine was 8.45ppm, 9.45ppm, 10.4ppm, 10.2ppm, and 10.7ppm. Maintenance informed me of shock being added to the pool I think that's what caused the high levels.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): the turnover for the pool shall reach a minimum of 6 per day. GPM was at 55 and needs to be at 88.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): the pool shall be kept from sediment & debris. There is staining around the inlets.

Jul 27, 2023

Routine

Score: 804 violations

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

13-189(c)(6): the water shall be of such clarity that the main drains are showing. The main drains are not visible. Maintenance supervisor added shock to the pool causing it to be super cloudy

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): the free chlorine residual in all parts of the pool shall be maintained between 3.0ppm-10.0ppm. It was twice at 1.80ppm and 1.93ppm. It spiked to 12.2ppm when the maintenance supervisor added the shock to the pool.

13 - float line in position

4 ptsCorrected: YesRepeat: No

13-202(i): the float line shall be placed at the 5 foot marker to indicate deeper waters. The float line wasn't set up upon inspection but the maintenance supervisor fixed it.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): pool shall be kept free from sediment and debris. There is severe staining towards the return inlets

Jun 13, 2023

Permit/Opening

Score: 933 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a): an adequately sized flow meter shall be operated continuously on the return line. The flow meter was on the return line but not operable.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(c)(3): bathrooms shall have water with a temperature range of 70 degrees Fahrenheit to 104 degrees Fahrenheit. There was no hot water upon testing.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): all pools shall be free of dirt and debris via brushing and vacuuming. There is staining around the return inlets and the pool surface was dirty. The surface needs to be brushed, acid washed, or resurfaced.