Decatur, DeKalb County

SWANTON HILL SUBDIVISION

109 TANYARD CREEK CT DECATUR, GA 30030

Pool
Latest score
89
Jun 11, 2026
City
Decatur
County
DeKalb
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 11, 2026

Routine

Score: 895 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c) pool water shall be tested for chlorine and pH at least 2 times per day. Observed: there are no chemical logs readily available

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1) depth markers must be indicated in feet and inches. Observed: there is no measurement for the depth markers

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(2) where depths are five feet or less there shall have "no diving" in minimum 2-inch lettering. Observed: lettering is about 3/4 inch

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: Yes

13-201(j) an adequately sized, covered and lined trash can shall be provided in sanitary facility area. Observed: the trash can in the men's bathroom has no lid

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-187(c) operating permit shall be displayed in a conspicuous place. Observed: permit displayed is from the previous year

May 4, 2026

Permit/Opening

Score: 952 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(2): Depth markers must be in feet and inches

“No Diving” signage shall have lettering at least 2 inches in height. Pool depth markings must be permanent, installed with tile or other approved materials, on a white background with numerals at least 4 inches high. Markings shall be clearly readable from the deck, located no more than 18 inches from the pool wall, and maintained with a slip-resistant finish.

Observation: No diving markers with international symbol, may be used in conjunction with the required "NO DIVING" 2 inch lettering

By next pool season (2027)

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(j) An adequately sized, covered and lined trash receptacle shall be provided in each men and women’s sanitary facility area.

Jul 1, 2025

Permit/Opening

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(2): Depth markers that state "No Diving" shall be minimum of 2 inches tall.

Observation: No diving markers are the international symbol, which is 1 inch tall. Advised to install the 2 incj "No Diving".

Aug 22, 2024

Re-inspection

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously on a twenty-four (24) hour basis to meet the minimum required turnover rate. Flow meter not operational.

Aug 20, 2024

Routine

Score: 747 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration no less than 3ppm and shall not exceed 10ppm. Pool was observed at 0.29ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The pool shall be maintained in an alkaline condition at all times between 7.2-7.8. Pool was observed at 7.0.

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

13-197(i): No disinfectant added by hand as the sole or primary method of adding chemicals. Liquid chlorine being fed from original container. No chlorine being fed through chlorinator.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously on a twenty-four (24) hour basis to meet the minimum required turnover rate. Flow meter not operational.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers shall be in black letters and numbers with a white background on the pool deck, indicated in feet and inches. The pool deck was observed to have a blue background with no feet indications.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c): Current inspection not observed.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-187(c): Expired operating permit observed.

Jun 21, 2024

Re-inspection

Score: 912 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(a): The equipment shall be operated continuously on a twenty-four (24) hour basis to meet the minimum required turnover rate. Pool was observed at 80 GPM, should be reaching 113 GPM.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1): Depth markers shall be in black letters and numbers with a white background on the pool deck, indicated in feet and inches. The pool deck was observed to have a blue background with no feet indications.

Jun 20, 2024

Re-inspection

Score: 763 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The pool shall be maintained in an alkaline condition at all times with pH between 7.2-7.8. pH reading at inspection is 6.9.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously on a twenty-four (24) hour basis to meet the minimum required turnover rate. Pool was observed at 80 GPM, should be reaching 113 GPM.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers shall be in black letters and numbers with a white background on the pool deck, indicated in feet and inches. The pool deck was observed to have a blue background with no feet indications.

Jun 18, 2024

Routine

Score: 754 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than 3ppm and shall not exceed 10ppm. Chlorine reading at inspection is 0.04ppm.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously on a twenty-four (24) hour basis to meet the minimum required turnover rate. Pool was observed at 45 GPM, should be reaching 113 GPM.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers shall be in black letters and numbers with a white background on the pool deck, indicated in feet and inches. The pool deck was observed to have a blue background with no feet indications.

24 - piping identified and marked

1 ptsCorrected: NoRepeat: No

13-191(a): All valves and piping in the equipment room shall be clearly labeled. Observed no labels on piping or valves.

May 16, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 16, 2023

Re-inspection

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(2) At shallow portions of pool or where depths are less than 5 feet shall have permanent NO DIVING in minimum 2inch letters (black), with white background. No diving markers observed are less than 2 inches.

Jun 15, 2023

Routine

Score: 813 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) A free Chlorine residual ranging from 3ppm to 10ppm must be maintained at all times. Chlorine reading at inspection is 0.31ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) The pool shall maintained in an alkaline condition at all times with pH between 7.2-7.8. pH reading at inspection is 7.0

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(2) At shallow portions of pool or where depths are less than 5 feet shall have permanent NO DIVING in minimum 2inch letters (black), with white background. No diving markers observed are less than 2 inches.