May 28, 2026

Permit/Opening

Score: 932 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-1909(a)(7): An adequately sized flow meter shall be installed on the return line. Observed flow meter not functional at the time of inspection. Observed flow meter not of adequate size. Minimum flow meter reading to reach required turnover is 175gpm. Observed flow meter with a maximum reading of 120 gpm.

16 - pool deck: maintained, unobstructed and clean

2 ptsCorrected: NoRepeat: No

13-188(h)(3): Pool deck shall not retain any standing water. Observed pool deck with standing water.

Jul 8, 2025

Permit/Opening

Score: 942 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) - equipment shall function 24 hours a day such that pool water experiences to achieve minimum adequate turnover every 6 hours observed: turnover rate was 50 gallons per minute, which indicates inadequate flow. Recommended to run backwash until water in sight glass runs completely clear to boost flowrate.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c)- Current inspection report shall be displayed conspicuously observed: Previous inspection not posted; advised to post by next inspection

Jun 17, 2025

Permit/Opening

Score: 765 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a) all gates/entrances to the pool must be self-latching, meaning able to swing shut and remain latched automatically observed: gates of both entrances were unable to latch automatically- informed CPO to grease springs to correct -imminent health hazard

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) - Chlorine levels for outdoor pools must be between 3 - 10 parts per million at all times observed: Chlorine levels were 2.40 and 1.96 ppm on test and retest, respectively. imminent health hazard

10 - pump: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

13-190(a) - Pump must be operational and all components must be operational, including return line observed: although pump was operational, very low water flow was observed, indicating circulation issues and potential piping issues imminent health hazard

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) - equipment shall be functional 24 hours a day to achieve adequate turnover every 6 hours observed: turnover rate was 20 gallons per minute, which indicates inadequate & unobservable flow

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-190(a), 13-190(a)(4) - skimmers and all components, including weirs, must be operational observed: 2 or 3 skimmers had no observable flow, were not operational, and did not have weirs imminent health hazard