Scottdale, DeKalb County

DOMAIN AT CEDAR CREEK APARTMENTS (POOL1)

3073 CEDAR CREEK PKWY DECATUR, GA 30033

Pool
Latest score
95
Jun 11, 2025
City
Scottdale
County
DeKalb
Inspections
10

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 11, 2025

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): Observed flow meter inoperable without a float present to measure the GPM. No accurate way to measure the flow rate. CA: An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate in gallons per minute (GPM); shall be conspicuously located.

Jun 9, 2025

Permit/Opening

Score: 763 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13.189(c)(1): chlorine should be kept between the range of 3.0 and 10.0 ppm at all times when the pool is operating.

  • free chlorine was observed at 1.01ppm. -Chlorine was in the chlorinator, chlorinator level was set to 4 of 5 levels. CPO stated that he will purchase new test kit to see if that would give better readings.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): Observed flow meter inoperable with bobble stuck at the bottom of the flow meter. No accurate way to measure the flow rate. CA: An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate in gallons per minute (GPM); shall be conspicuously located.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

Observed Cyanuric acid levels at 131ppm. Cyanuric may not exceed a level of 100ppm. Discussed with CPO that the pool must be drained half way and then refilled with fresh water.

May 23, 2025

Permit/Opening

Score: 802 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13.189(c)(1): chlorine should be kept between the range of 3.0 and 10.0 ppm at all times when the pool is operating.

  • free chlorine was observed at 0.11ppm. -Chlorine was in the chlorinator, chlorinator level was set to 4 of 5 levels. CPO stated that he will purchase new test kit to see if that would give better readings.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): Observed flow meter inoperable with bobble stuck at the bottom of the flow meter. No accurate way to measure the flow rate. CA: An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate in gallons per minute (GPM); shall be conspicuously located.

May 22, 2025

Permit/Opening

Score: 783 violations

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13.189(c)(1): chlorine should be kept between the range of 3.0 and 10.0 ppm at all times when the pool is operating.

  • free chlorine was observed at 0.02 and 0.11 -CPO stated that there wasn't any chlorine in the chlorinator, CPO added chlorine to the chlorinator and turned the chlorinator up to level 5.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): Observed flow meter inoperable with bobble stuck at the bottom of the flow meter. No accurate way to measure the flow rate. CA: An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate in gallons per minute (GPM); shall be conspicuously located. -CPO will fix flow meter by next inspection.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

13-184(e)(5): unsecured handrail is considered an imminent health hazard. -Observed ladder rail without steps to the ladder. -CPO stated that he will order steps and secure them to the rail.

Aug 2, 2024

Re-inspection

Score: 813 violations

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13.189(c)(1): chlorine should be kept between the range of 3.0 and 10.0 ppm at all times when the pool is operating.

  • free chlorine was observed at 1.68 and 2.11
  • able to raise fcl to 3.40 before end of inspection

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH must be maintained between 7.2 and 7.8. -initially measured at 6.7 -raised to 7.3 before conclusion of inspection.

13 - float line in position

4 ptsCorrected: NoRepeat: No

13-202(l): float line should be in place upon the slope break where depths exceed 5 feet. -multiple broken buoys on the float line. -informed me that they had ordered an replacement.

Jul 16, 2024

Routine

Score: 737 violations

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

At all times water clarity should be kept so that the main drains at the deepest part of the pool are clearly visible.

  • water was cloudy at time of inspection.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13.189(c)(1): chlorine should be kept between the range of 3.0 and 10.0 ppm at all times when the pool is operating.

  • free chlorine was observed at 0.02 ppm

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

13-197(a): water shall be continuously chemically treated with an approved disinfectant. -chlorinator was observed to be low in tablets.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-202: must maintain daily record of chemicals. -log had not been updated since July 6, 2024.

13 - float line in position

4 ptsCorrected: NoRepeat: No

13-202(l): float line should be in place upon the slope break where depths exceed 5 feet. -observed multiple broken buoys on the float line. -could be sharp and harmful to bathers and must be fixed.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

13-184(e)(5): unsecured handrail is considered an imminent health hazard. -ladder handrail was observed to be loose and came out of pool deck upon pulling.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): pool shall be kept free of debris. -leaves observed on the bottom of the pool.

Jun 12, 2024

Re-inspection

Score: 802 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c): pH must be maintained between 7.2 and 7.8 at all times. -measured at 7.0 initially. -was able to correct while on site.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): the equipment shall operate on a 24 hour basis and reach 6 turnovers. The GPM was at 90 and should be around 167 GPM.

Jun 3, 2024

Routine

Score: 746 violations

2 - self-closing / self-latching gates

15 ptsCorrected: YesRepeat: No

13-202: entry to the pool must be through a self closing gate. -one gate has a non-functional latch and was open when I arrived. operator placed padlock on the gate. emphasized that it must remain padlocked at all times until latch repaired.

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(3): when pool is not open for use access to pool should prohibited by closing and securing all gates. Must display a sign that reads "pool closed" -operator claimed that pool was closed for maintenance when I arrived, but there was no sign.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): free-chlorine must be at least 3ppm for outdoor pools at all times.

  • free chlorine was less than one parts per million. Must make sure chlorine is at appropriate levels before reinspection

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): the equipment shall operate on a 24 hour basis and reach 6 turnovers. The GPM was at 100 and should be at 140.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-202(c): operators should maintain records of daily disinfectant levels and pH, and maintenance. -records not taken daily; no indication of corrections when chemicals out of required range.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): all pools shall be kept free from sediment, dirt or debris by frequent brushing and vacuuming. visible scum should be removed immediately. -observed debris & litter at the bottom of the pool.

May 7, 2024

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed deck cracking, repair.

Jul 11, 2023

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): the equipment shall operate on a 24 hour basis and reach 6 turnovers. The GPM was at 120 and should be at 140.