Peachtree City, Fayette County

Holiday Inn Hotel

203 NEWGATE RD PEACHTREE CITY, GA 30269

Pool
Latest score
94
May 14, 2026
City
Peachtree City
County
Fayette
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 14, 2026

Permit/Opening

Score: 944 violations

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

The letters on the depth marker do not meet minimum height requirement of 4". Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct prior to permitting season 2028

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The words "No Diving" does not meet the minimum height requirements for the depth markers. There is no universal symbol for No Diving present at each depth marker. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

The "No Lifeguard on Duty" sign does not meet the code requirements. The portion for "supervise children closely" does not meet minimum letter height of 4 inches. Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

The complete list of pool risks is not posted. See attachment on email for complete list of required pool risks.

Jul 22, 2025

Routine

Score: 748 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed that the emergency phone dialed to the front desk and not 911 directly. CA: Emergency phone shall be capable of calling 911 directly.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed daily water testing records were not available while on site. CA: Facility shall have daily water testing records available.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

Observed that there were no float valve assembly in skimmer. CA: Skimmer equalizer lines shall be protected by an approved cover.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed that there were no weirs present in the skimmers. CA: Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

Observed wrong covering for equalizer line. CA: The equalizer lines shall be protected by an approved covering.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

Observed the no lifeguard on duty sign did not have "RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY" on the sign. CA: Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed no diving markings but no universal international symbol for "no diving" was present; observed that the "FT" was not 4 inches tall. CA: The universal international symbol for “NO DIVING” shall be permanently visible; the depth markers shall be 4 inches in size.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Observed all that not all required pool risks are posted. CA: All required pool risks shall be posted.

May 5, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 1, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Apr 18, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 22, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 27, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.