Peachtree City, Fayette County

Georgian Park Condominiums (Main Pool)

100 LAS BRASIS CT PEACHTREE CITY, GA 30269

Pool
Latest score
92
Jun 3, 2026
City
Peachtree City
County
Fayette
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 3, 2026

Permit/Opening

Score: 922 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

There is an equalizer line cover that does not have the correct cover. The line is covered with an inlet cover. Remove inlet cover and protect the equalizer line with the appropriate cover. The skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater. Suction outlets shall be provided with a cover that has been tested and approved by a nationally recognized testing laboratory and shall comply with the current ANSI/APSP16 , Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs. Must be corrected by routine inspection.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

The pressure gauge is not functioning properly. Replace gauge.

May 8, 2025

Permit/Opening

Score: 942 violations

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Replace missing depth and no diving markers.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Repair pool deck where it is cracked.

Apr 29, 2025

Permit/Opening

Score: 794 violations

3 - compliant drain covers secure, present and no cracks

Regulation: 511-3-5-.23(5)(f) - (f) broken, unsecured, or missing main drain, or any submerged suction outlet cover/grate

15 ptsCorrected: NoRepeat: No

Replace damaged drain cover. Grate is broken.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Repair phone line so that it is operational.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Replace missing depth and no diving markers.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Repair pool deck where it is cracked.

Aug 1, 2024

Routine

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: .06(3)(e) - markings

4 ptsCorrected: NoRepeat: No

Replace missing depth and no diving markers.

May 2, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 7, 2023

Routine

Score: 942 violations

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Provide daily records of pool tests.

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: NoRepeat: No

Place inspection report in public view.