May 22, 2026
Permit/Opening
17 - skimmers/gutters maintained and operable
Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.
There is an equalizer line cover that does not have a cover. The line is covered with an inlet cover. Remove inlet cover and protect the equalizer line with the appropriate cover. The skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater. Suction outlets shall be provided with a cover that has been tested and approved by a nationally recognized testing laboratory and shall comply with the current ANSI/APSP16 , Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs. Must be corrected by routine inspection.
22 - signs: peak occupancy/pool/spa/signs legible and in clearview
Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
he words "No Diving" does not meet the minimum height requirements for the depth markers. There is no universal symbol for No Diving present at each depth marker. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.