Peachtree City, Fayette County

Coventry (Wading Pool)

CLOISTER DR PEACHTREE CITY, GA 30269

Pool
Latest score
70
May 20, 2026
City
Peachtree City
County
Fayette
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 20, 2026

Permit/Opening

Score: 7010 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

The pool access gate does not latch back when opened at different angels. Ensure the access gate properly latches to prevent unauthorized access.

Must be in compliance prior to permitting. Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

The emergency phone functions. However, the address indicated by 911 emergency does not match the location address. Emergency services must have the correct address associated when called to prevent a delay in response time for emergency services. Must be corrected prior to permitting. An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

The chlorine exceeds the maximum allowance of 10ppm. Reduce chlorine. Must be corrected prior to permitting. Chlorine in stabilized pools must be between 2pp-10ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

The pH exceeds the maximum allowance of 7.8. pH should be maintained between 7.2 and 7.8. Must be corrected prior to permitting

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

The letters on the depth marker do not meet minimum height requirement of 4" and are not permanent in nature- on stickers. Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct prior to permitting season 2028

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

A weir is not present in each skimmer. Replace weirs. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

There is no available documentation to show there is a current, certified CPO associated with the pool. The trained operator shall have a current certificate showing completion of an approved operator training course. A copy of the original certificate or documentation shall be available onsite for inspection by the Health Authority.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The No Diving marking and universal symbol for No Diving are not permanent in nature on the deck and No Diving does not meet the proper letter height requirement of 4". The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. These must be in compliance prior to permitting 2028

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.17(2) The alkalinity exceeds the maximum requirement. Alkalinity is required to be at 60ppm minimum and 180 ppm maximum. Speak with CPO about adjusting the alkalinity in the pool, then verify the pH is within proper range.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.17(2): The is insufficient calcium hardness in the pool. hardness is required to be at 150 ppm minimum and 1000 ppm maximum. Speak with CPO about adjusting calcium in the pool.

Apr 29, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 24, 2024

Routine

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: .06(3)(e) - markings

4 ptsCorrected: NoRepeat: No

Replace missing no diving tiles on pool deck.

Apr 1, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 24, 2023

Routine

Score: 951 violation

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Provide records of daily water testing.