Jan 29, 2026
Routine
12C - wiping cloths: properly used and stored
Regulation: 511-6-1.04(4)(m) - wiping cloths, use limitation (c)
Observed towels in chlorine sanitizing solution at 10ppm. PIC remade the sanitizer to 50ppm.
16B - plumbing installed; proper backflow devices
Regulation: 511-6-1.06(2)(r) - system maintained in good repair (p, c)
Observed a leak underneath the women's restroom sink. PIC stated that two plumbers have already come to try and fix the repairs, but the leak is still present. Please have the leak repaired no later than 2/9/2026 and send the repair invoice to keundra.golden@dph.ga.gov.
14A - in-use utensils: properly stored
Regulation: 511-6-1.04(4)(k) - in-use utensils, between-use storage (c)
Observed fryer oil skimmer stored on a surface with food debris in between fryer and grill. PIC was advised to clean the surface area and the skimmer.
15C - nonfood-contact surfaces clean
Regulation: 511-6-1.05(7)(a)2,3 - equipment, food/nonfood-contact surfaces, and utensils, food-contact surfaces of cooking equipment & nonfood-contact surfaces free of accumulations (c)
Observed food build up on the shelf inside of the double door freezer. Observed food debris on the bottom of the single door reach-in freezer. Observed shelf above the rice cookers in need of cleaning. Observed shelf on the cooking line where single use to-go plates are stored in need of cleaning. PIC was advised to look into getting shelf liners for the cookline that were non-absorbent and cleanable. Observed excessive food and grease build up underneath the grill and on the sides of the fryers.
15C - nonfood-contact surfaces clean
Regulation: 511-6-1.05(7)(d) - nonfood-contact surfaces (c)
Observed mold like substances around the caulking of the 3 compartment sinks. PIC was advised to remove old caulk, clean and sanitize area, and recaulk the sink.
17C - physical facilities installed, maintained, and clean
Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)
Observed walls underneath the prep sinks and 3 compartment sinks in need of cleaning due to debris.