Hinesville, Liberty County

Treetop Apartments Pool

600 TAYLOR RD HINESVILLE, GA 31313

Pool
Latest score
100
Jun 9, 2026
City
Hinesville
County
Liberty
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 9, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 23, 2025

Routine

Score: 854 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: No

Observed flow meter for this pool reading 80 gpm. Minimum flow rate required for 6-hour turnover is 92 gpm for this pool.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed daily water testing has not been done since August.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(5) - (5) the trained operator must perform a minimum of two visits weekly and be able to provide assistance whenever needed.

4 ptsCorrected: NoRepeat: No

Observed the CPO has not performed water tests since August. CPO must check pool at least twice weekly.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

Observed no paper towels in either restroom. Observed no soap in women's restroom.

Jul 29, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 21, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 18, 2023

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone is connected to office phone and is not readily available for emergency situations.

511-3-5-.18(10)(c ) - (c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. (c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby