Hinesville, Liberty County

Hinesville Wading Pool

607 E OGLETHORPE HWY HINESVILLE, GA 31313

Pool
Latest score
94
May 21, 2026
City
Hinesville
County
Liberty
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 21, 2026

Permit/Opening

Score: 942 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: No

Observed no flow registering on flow meter

31 - dressing showers: clean, maintained, hot and cold water available

Regulation: 511-3-5-.19(1)(e ) - (e) hot and cold water under pressure shall be provided in dressing facility showers.

1 ptsCorrected: NoRepeat: No

Observed no hot water in showers or sinks in either locker room.

Jul 22, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 22, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 24, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 23, 2024

Routine

Score: 851 violation

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed wading pool pH reading at 7.0. Wading pool voluntarily closed for the day until pH could be addressed. CPO to get pH to 7.2 prior to opening. CPO will contact inspector once pH has been corrected.

May 15, 2024

Permit/Opening

Score: 933 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter not registering a flow rate

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Observed no labels or directional arrows on pipes

31 - dressing showers: clean, maintained, hot and cold water available

Regulation: 511-3-5-.19(1)(e ) - (e) hot and cold water under pressure shall be provided in dressing facility showers.

1 ptsCorrected: NoRepeat: No

Observed no hot water in showers or sinks in either locker room.

May 25, 2023

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: Yes

Observed the flow meter was not registering the flow rate of the wading pool.

511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.