May 15, 2023
Permit/Opening
1 - barrier: pool enclosed/fencing in compliance
Regulation: 511-3-5-.18(11)(b) - (b) openings in the barrier shall not allow passage of a four inch diameter sphere.
Fence spacing must be 4" or less, repair missing fence vertical members
2 - self-closing / self-latching gates
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Gate is not self-latching
7 - ph between 7.2 and 7.8
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
PH is 7.9, 7.8 is the max
10 - pump: approved, maintained and operating
Regulation: 511-3-5-.09(1) - (1) sizing. a pump and motor shall be provided for circulation of the pool and spa water. performance of all pumps shall meet or exceed the conditions of flow required for filtering and cleaning (if applicable) the filters against the total dynamic h
Required flow of 102.7 gpm is not met. 65 gpm recorded.
11 - appropriate lifesaving equipment present
Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch
Coast Guard approved life ring required
28 - flow meter: appropriate range and location
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flow meter too small for required size
36 - daily recordkeeping: water testing and self inspection performed
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
No evidence of water testing
18 - combined chlorine level 0.4 ppm or less
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
Combined chlorine measured at 1.2, must be 0.4 or less
19 - adequate turnover rate
Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Turnover rate not met
35 - operator facility inspections performed; written documentation
Regulation: 511-3-5-.22(5) - (5) the trained operator must perform a minimum of two visits weekly and be able to provide assistance whenever needed.
Daily inspections wit records required. Records should be available upon request
13 - float line in position
Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of
Float Line Required
15 - depth and no diving markers, step marking; installed and contrasting
Regulation: 511-3-5-.18(4) - (4) depth markers for spas. public spas shall have permanent depth markers with numbers and letters a minimum of four inches high plainly and conspicuously visible from all obvious points of entry and in conformance with subsections (a) thru (f) belo
"No Diving" lettering must be 4" high
17 - skimmers/gutters maintained and operable
Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.
Skimmers must be fully operational for permitting
22 - signs: peak occupancy/pool/spa/signs legible and in clearview
Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:
No peak occupancy signs