Jul 22, 2025
Re-inspection
7 - ph between 7.2 and 7.8
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed pH above 7.8. Advised to adjust. COS pH at 7.6
2615 MT. ZION PKWY JONESBORO, GA 30236
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed pH above 7.8. Advised to adjust. COS pH at 7.6
Permit/Opening
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed pH above 7.8 in the pool. Advised to adjust
Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Observed flow meter not meeting turnover rate. Advise to adjust
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Observed ladder in pool not capped off. Advised to cap off
Routine
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Skimmers observed filled with leaves. Advised to clean.
Permit/Opening
Permit/Opening