ATLANTA, DeKalb County

TWIN LAKES CENTER (MAIN POOL)

2841 BRIARLAKE RD ATLANTA, GA 30345

Pool
Latest score
85
Jun 5, 2026
City
ATLANTA
County
DeKalb
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 5, 2026

Routine

Score: 851 violation

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: YesRepeat: No

1st chlorine reading was 1.51 ppm and the 2nd reading was 4.84 ppm.

Apr 30, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 16, 2026

Permit/Opening

Score: 804 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g): an operable, hard wired, weatherproof telephone with direct 911 access installed in a conspicuous location shall be readily available at all times within the pool enclosure. Observed phone functional, with drastically wrong address listed with 911 operator.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Permanent, slip-resistant, easily readable depth markers at least 4 inches high with black letters and numbers on a white background indicated in feet and inches are required. Observed one depth marker missing number tile (10).

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(k): Pool shall be supplied with a readily available first aid kit kept supplied and ready for use. Observed first aid kit in disrepair.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-190(a)(8): Pools equipped with heaters shall have an unbreakable thermometer designed for pool use available for bathers and pool staff to monitor pool water temperatures. Observed no pool thermometer present at time of inspection.

Aug 18, 2025

Routine

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

10 ft depth marker still missing

Jun 5, 2025

Routine

Score: 942 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

One 10ft depth marker was missing.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: YesRepeat: No

Grab rails were not anchored to the pool deck. Each rail was corrected on site.

Apr 4, 2025

Permit/Opening

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: YesRepeat: No

13-184(e)(5)Unsecured handrails considered an imminent health hazard.

Observed the deep end ladder by the water slide and the ladder by the 4 ft marker in front of the water slide unsecured. COS: CPO secured ladders to the deck.

Jul 1, 2024

Routine

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(a): The equipment shall be operated to obtain the minimum required of one turnover every 4 hours. Flowmeter showed a reading of 450 gpm. It should be a minimum of 500 gpm.

Jun 4, 2024

Routine

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(a): The equipment shall be operated to obtain the minimum required of one turnover every 4 hours. Flowmeter showed a reading of 180 gpm. It should be a minimum of 500 gpm.

Apr 17, 2024

Permit/Opening

Score: 932 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

equipment shall obtain the minimum required one turnover every 6 hours (500 gpm). Observed flow meter reading 350gpm

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

Observed unsecured ladders in the deep end of the pool. COS: Ladders were secured.

Aug 8, 2023

Routine

Score: 894 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) - equipment shall obtain the minimum required one turnover every 4 hours (750 gpm). Observed flow meter reading 350gpm

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a)(4) Each skimmer shall have a properly designed and operating weir or other departmentally approved means of providing effective skimming. Observed skimmers without weirs.

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: No

13-201(k) - at all times an adequate amount of liquid soap shall be provided. Observed no liquid soap in showers.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c) - current inspection report shall be displayed where it is easily readable by the public.

Jun 16, 2023

Routine

Score: 735 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: YesRepeat: No

13-189(c)(1) The pool shall be maintained in an alkaline condition at all times with a pH level between 7.2 – 7.8. Pool pH was at 7.9 at the time

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required or one turnover every 4 hours

17 - skimmers/gutters maintained and operable

4 ptsCorrected: YesRepeat: No

13-196(a)(4) Each skimmer shall have a properly designed and operating weir or other departmentally approved means of providing effective skimming. Clean out skimmers. Two skimmers barely had any suction

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: YesRepeat: No

13-202(m) Safety rules and regulations shall be easily readable and shall be conspicuously posted in the pool area. Pool sign was incomplete. Bather load and hours of operation missing

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: YesRepeat: No

13-201(k) At all times, an adequate supply of liquid soap, toilet paper and paper towels shall be provided and stored in appropriate dispensers conveniently accessible to users. Showers did not have supply of liquid soap