MICROTEL INN & SUITES

1840 CORPORATE BLVD ATLANTA, GA 30329

Tourist
Latest score
100
May 28, 2026
City
Brookhaven
County
DeKalb
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 28, 2026

Routine

Score: 1000 violations
No violations recorded for this inspection.

Sep 10, 2025

Routine

Score: 932 violations

3 - hot/cold running water under pressure in all required locations of tourist accommodation

Regulation: 511-6-2-.07(2) - hot water supply

5 ptsCorrected: NoRepeat: No

Observed several rooms with hot water exceeding 120*F. CA: Advised PIC Cold running water under pressure shall be provided to all equipment that uses water. Hot and cold running water under pressure shall be provided to all lavatories, bathing facilities, laundry facilities, and water-using equipment where eating and drinking utensils are washed. In all new tourist accommodations, and where possible in existing tourist accommodations, hot water in all guest rooms shall not exceed 120F. PIC has been advised to lower the boiler and provide an update via email to tairyn.broadnax@dph.ga.gov

10 - permit and inspection report current and properly displayed; pic assigned

Regulation: 511-6-2-.05(7) - inspection posting

2 ptsCorrected: NoRepeat: No

Observed expired inspection report posted (94/A) . CA: Advised PIC The most recent tourist accommodation inspection report form shall be prominently displayed in public view at all times, between five feet and seven feet from the floor and in a public area such as the registration desk, where it can be read at a distance of one foot away

Jan 2, 2025

Routine

Score: 942 violations

3 - hot/cold running water under pressure in all required locations of tourist accommodation

Regulation: 511-6-2-.07(2) - hot water supply

5 ptsCorrected: NoRepeat: No

Observed hot water at 126F in room 303, 126F in room 304, 123F in room3 305, 129F in room 218 , 130F in room 225 and 123F in room 209Cold running water under pressure shall be provided to all equipment that uses water. Hot and cold running water under pressure shall be provided to all lavatories, bathing facilities, laundry facilities, and water-using equipment where eating and drinking utensils are washed. In all new tourist accommodations, and where possible in existing tourist accommodations, hot water in all guest rooms shall not exceed 120F

15 - ice from approved source; properly handled, supplied and stored; equipment approved/clean

Regulation: 511-6-2-.07(8) - ice supply

1 ptsCorrected: NoRepeat: Yes

Observed debris build-up present along the panel inside the ice shoot during time of inspection. CA: Advised PIC the use of existing self-service ice-storage bins may be continued, provided that the machines are maintained in good repair and capable of being properly cleaned and sanitized according to the manufacturer’s recommendations

Apr 2, 2024

Routine

Score: 923 violations

8 - annual gas fired equipment inspection on file; gas units equipped with automatic safety and/or 100% cut-off pilot

Regulation: 511-6-2-.15(5) - heating and fire safety-inspection

5 ptsCorrected: NoRepeat: No

Observed PIC unable to provide annual fire safety inspection. CA: Advised PIC all gas-fired equipment shall be inspected at least annually by a qualified licensed contractor or local fire authority, if available. Points to be inspected are proper construction and installation, malfunctions and adjustments of controls and burners, faulty heat exchangers and vent obstructions. Any defects found on inspection must be corrected by a qualified heating contractor prior to use of the equipment. Upon request, the operator shall provide evidence of inspection and/or correction of any deficiency

10 - permit and inspection report current and properly displayed; pic assigned

Regulation: 511-6-2-.04(1)a - permit display

2 ptsCorrected: NoRepeat: No

Observed expired TA permit posted upon arrival. CA: Advised PIC to obtain and post the most current permit in public view

15 - ice from approved source; properly handled, supplied and stored; equipment approved/clean

Regulation: 511-6-2-.07(8) - ice supply

1 ptsCorrected: NoRepeat: Yes

Observed debris build-up present along the panel inside the ice shoot during time of inspection. CA: Advised PIC the use of existing self-service ice-storage bins may be continued, provided that the machines are maintained in good repair and capable of being properly cleaned and sanitized according to the manufacturer’s recommendations

Sep 19, 2023

Routine

Score: 982 violations

14 - single service items placed in guestrooms or dwelling units commercially pre-wrapped

Regulation: 511-6-2-.07(6) - single service items

1 ptsCorrected: NoRepeat: Yes

Observed single service lids placed in rooms inspected not properly wrapped. CA: Advised PIC Single-service items placed in a guestroom or dwelling units shall be commercially pre-wrapped to protect against contamination

15 - ice from approved source; properly handled, supplied and stored; equipment approved/clean

Regulation: 511-6-2-.07(8) - ice supply

1 ptsCorrected: NoRepeat: Yes

Observed black/pink debris build-up along the inside of the ice machine. CA: Advised PIC to clean to avoid cross contamination