May 14, 2026
Permit/Opening
15 - depth and no diving markers, step marking; installed and contrasting
Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
The letters on the depth marker do not meet minimum height requirement of 4". Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct prior to permitting season 2028
21 - cyanuric acid level not exceeding maximum
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
he cyanuric acid level exceeds the maximum allowance of 90 ppm. Reduce CYA to get maximum effectiveness of the chlorine. Stabilizer (if used) Cyanuric acid, ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas.
22 - signs: peak occupancy/pool/spa/signs legible and in clearview
Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
The words "No Diving" does not meet the minimum height requirements for the depth markers. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.
22 - signs: peak occupancy/pool/spa/signs legible and in clearview
Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
The peak occupancy for the pool is not posted. The peak occupancy is 51. A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
37 - other violations of the chapter
.11(3)(e) There is no equalizer check valve and float valve assembly present in each skimmer. Each skimmer shall be equipped with a trimmer valve capable of distributing the total flow between individual skimmers. Items have been ordered