Aug 26, 2025
Re-inspection
28 - flow meter: appropriate range and location
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed that the flow meter is not properly working. CA: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided.
36 - daily recordkeeping: water testing and self inspection performed
Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
Observed that there is no available information to verify a daily safety check is being performed. CA: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
36 - daily recordkeeping: water testing and self inspection performed
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
Observed there are no available records onsite to verify twice daily chemical testing is performed. CA: The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. The water quality testing frequency shall be completed based on the requirements of the code.
15 - depth and no diving markers, step marking; installed and contrasting
Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
Observed that the lettering on the depth markers on the pool wall are not properly sized. CA: Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied.
17 - skimmers/gutters maintained and operable
Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.
The float check valves are missing. CA: Skimmer lines shall be properly protected.