Brunswick, Glynn County

Cove at Golden Isles

3200 CYPRESS MILL RD BRUNSWICK, GA 31525

Pool
Latest score
100
May 27, 2026
City
Brunswick
County
Glynn
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 27, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 22, 2026

Routine

Score: 851 violation

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Observed water with low clarity with the MD covers unable to be seen at the time of this inspection. CA: Ensure water is clear enough to see the MD covers at all times.

Oct 28, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 22, 2025

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed an inoperable flow meter during the course of this inspection. CA: Repair or replace flow meter.

Aug 19, 2024

Routine

Score: 844 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed an inoperable flow meter during the course of this inspection. CA: Repair or replace flow meter.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed facility without documentation of the twice daily water tests and self inspection at the time of this inspection. CA: Ensure twice daily water tests are completed along with the daily self inspection with documentation.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed high CYA level at the time of this inspection. CA: Ensure CYA does not exceed 90ppm.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Observed holes in the pool surfacing at the time of this inspection. CA: Repair holes before next permitting inspection or risk closure.

Apr 29, 2024

Permit/Opening

Score: 932 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed a low turnover rate at the time of this inspection. CA: Ensure turnover is raised to the minimum of 121Gpm.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Observed holes in the pool surfacing at the time of this inspection. CA: Repair holes before next permitting inspection or risk closure.

Nov 21, 2023

Routine

Score: 981 violation

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Observed cracked decking around the pool edge on the deep end side at the time of this inspection. CA: Facility will have this repaired to prevent possible injury.