Brunswick, Glynn County

Cove at Fountain Lake, The

1105 FOUNTAIN LAKE DR BRUNSWICK, GA 31525

Pool
Latest score
93
May 22, 2026
City
Brunswick
County
Glynn
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 22, 2026

Permit/Opening

Score: 932 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine levels above 0.4 ppm. CA: Lower combined chlorine levels to 0.4 ppm.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Observed pool deck near the stairs with significant damage at the time of this inspection. CA: Repair damage

Aug 27, 2025

Routine

Score: 764 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed a low chlorine level at the time of this inspection. CA: Ensure chlorine level is 2.0-10.00ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed a high pH level at the time of this inspection. CA: Ensure pH ranges 7.2-7.8.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter stuck at the bottom, making it impossible to read the flow rate at the time of this inspection. CA: repair flow meter so the flow rate may be read.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Observed pressure gauges unreadable at the time of this inspection. CA: Replace pressure gauge so the numbers are visible.

Jul 3, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jun 12, 2025

Permit/Opening

Score: 851 violation

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Observed pool green with main drains not visible from the pool's edge at the time of this inspection. CA: Ensure pool water is clear enough to be able to see the main drains at all times.

Apr 29, 2024

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed a low turnover rate at the time of this inspection. CA: Ensure turnover rate is increased to a minimum of 80GPM.

Nov 21, 2023

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed a high CYA at the time of this inspection. CA: Lower CYA to 90ppm or less.

Jun 1, 2023

Permit/Opening

Score: 942 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed skimmer lids are homemade out of plexi glass. CA: Staff spray painted them orange for now. New lids for skimmers are on order.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Observed pool deck in disrepair with gaps and vertical elevations and coping with gaps along tile line. CA: Facility added silicone filler to coping for the time being. FAcility will plan for a full repair to ensure 1. coping joints are water tight and do not pose injury risk and 2. decking gaps and vertical elevations are minimized to acceptable standard.